|
|

Atlantis is an entirely new concept in EEG and biofeedback systems. It goes beyond the current state-of-the-art, to define a new approach to high-quality and effective EEG and peripheral feedback. It includes an innovative “Triamptm” bioamplifier that records and reports the EEG signal, the DC and slow cortical potentials, and the impedances of the sensors as well, continuously, and in real time. In addition to 4 (24-bit) EEG channels, there are 4 (12-bit) Aux channels, also using Triamptm inputs, providing simultaneous AC, DC, and impedance recording for skin, muscle, heart, temperature, and other peripheral modalities. In addition, its built-in “autonomous” functions provide rapid (1024 events/second) real-time feedback for real-time photic, auditory, and vibrotactile stimulation. Atlantis is more than an EEG or biofeedback encoder. In incorporates powerful hardware and software technology to provide an integrated system that performs autonomous real-time EEG-controlled feedback without a PC, as well as providing real-time data for PC-based software. The Atlantis is capable of recording and processing EEG in real-time (typical rate 1024 samples per second), and providing live feedback in the form of photic stimulation, auditory feedback, and vibrotactile feedback, all operating at 1024 samples/second. This provides rapid and accurate feedback for sensitive “desynchrony” or “inhibit-based” protocols that depend on real-time EEG-controlled response. These response speeds are not possible with PC-based software, owing to the delays inherence in PC and Windows-based systems. Only a dedicated, real-time hardware solution (analog or digital) can provide this type of guaranteed response and feedback. Atlantis provides “total immersion”. By providing simultaneous real-time feedback in the forms of photic stimulation, auditory stimulation, and vibrotactile stimulation, Atlantis produces an immersive sensory experience that is comprehensive yet simple. In its simplest form, the EEG signal is fed directly back to the trainee in the form of signals encoded into the LED glasses, the speakers or headphones, and the vibrotactile cushion. This feedback does not depend on specific protocols, and is more “analog” in nature than conventional “discrete” training (e.g. PC-based) paradigms. Feedback can be used to provide either reinforcement or inhibition of EEG or other biological rhythms via. direct sensory feedback, based upon on the EEG connections used, and the details of the feedback settings. Those who have experienced and appreciate the value of dedicated real-time analog or digital feedback systems will understand the value of this approach, and see it as an important component of a comprehensive neurofeedback capability. In addition to its innovative autonomous functions, Atlantis incorporates continuous real-time impedance monitoring (not impedance “checking”). All impedances on the EEG as well as the Aux channels can be continuously monitored via, the front panel LED’s, or via. PC-based software. The 4 EEG channels include built-in LED indicators showing the impedance values continuously on the front-panel, throughout the training session. This is vastly superior to impedance “checkers” that only monitor impedance when requested, and which require data acquisition to stop during impedance checking. Atlantis provides continuous monitoring of all EEG impedances, as well as the ability to send impedance data back to the PC for feedback and intervention, when needed. This capability virtually eliminates the need for a separate impedance-checking step, and ensures that all impedances are within desired ranges, at all times during the feedback session. The Atlantis system also includes direct-current (DC) and slow-cortical potential (SCP) measurement, using our innovative Triamptm amplifier design. With this system, you will be able to simultaneously and continuously measure, on each EEG channel, the EEG signal, the impedances of both the active and reference leads, the DC potential, and the SCP potential, all at the same time. This opens important new avenues for research and clinical work with DC and SCP potentials, as well as with conventional (now wideband 0.0 – 120.0 Hz) EEG signals. Because the Atlantis EEG inputs are sampled with 24 bits at 1024 samples/second and reconstructed for data transmission to the PC, the EEG channels can be used to monitor EMG, EKG, or other “fast” signals without aliasing errors due to undersampling. When data are transmitted at 256 samples per second, the operating bandwidth of the system becomes 0.0-120.0 Hz. The ability to go cleanly and uniformly to 120 Hz provides new possibilities in EEG as well as EMG and related signal training. Thus, useful high-resolution biofeedback training can be done on muscle, heart, and other biological signals without loss of accuracy. When faster signal training is required, the Atlantis can operate in its “native” mode, and acquire and send data as fast as 8192 samples/second. Thus, research and clinical training can be done with signals ranging in bandwidth from DC to 4096 Hz, in selected modes. EEG: Number of EEG channels: 4 Amplifier type: BrainMaster Triamptm (simultaneous AC/DC/Impedance recording) Inputs: Bipolar: Separate Active, Reference per channel, shared isolated ground EEG A/D Resolution: 24 bits EEG A/D Accuracy: 0.023 microvolts EEG A/D Full Scale Range: +/- 190 microvolts Typical EEG internal sampling/operating rate (4 channels): 1024 samples/second (with continuous impedance monitoring) Maximum EEG sampling rate ( 4 channels): 4096 samples/second (without continuous impedance monitoring) Maximum EEG sampling rate (1 channel): 8192 samples/second (without continuous impedance monitoring) Common-mode Rejection Rati > 120dB Input Impedance: > 1000 GOhm Input noise: < 0.5 microvolts Typical Operating Bandwidth: 0.0 (DC) – 120.0 Hz typical (1024 samples/second internal, 256 samples/second sent to PC) Maximum Operating Bandwidth (4 channels): DC – 2048 Hz. (4096 samples/second internal, 4096 samples/second sent to PC) Maximum Operating Bandwidth (1 channel): DC – 4096 Hz. (8192 samples/second internal, 8192 samples/second sent to PC) Continuous sensor impedance monitoring for EEG: Amplifier type: BrainMaster Triamptm (simultaneous AC/DC/Impedance recording) Inputs: Single Ended: Single Active per channel, shared isolated ground Resolution: 12 bits Impedance range: 0 – 1 Megohm Impedance accuracy: < 0.5 Kohm Front panel indicators: tri-color LED’s indicating impedance via color and flash rate Separate indicators for active and reference leads (total 8 indicators for 4 channels) Impedance Indicator Levels: <5K, <10K, <20K, <50K, <100K Impedance data may be continually sent to PC and monitored using BrainMaster 3.0 SW Aux: Number of Aux channels: 4 Aux A/D Resolution: 12 bits Aux A/D Accuracy: 0.2 millivolts Aux A/D Full Scale range: 0-2.5 volts Aux Typical sampling rate: 1024 samples/second (with continuous impedance monitoring) Aux Maximum sampling rate: 8192 samples/second (without continuous impedance monitoring) Aux impedance monitoring: 12-bit accuracy, range 10 Megohms Internal Autonomous Functions: Operating rate: 1024 samples/second Modes: photic, vibrotactile, auditory feedback Photic: direct real-time EEG-controlled photic stimulation via built-in controller Auditory: direct real-time auditory feedback of EEG via. built-in controller Vibrotactile: direct real-time tactile feedback of EEG via. built-in controller NOW AVAILABLE CALL FOR DETAILS!! 440-232-6000 ATLANTIS 1 4x4 Including 2.5SE Software list price $2695 (less 15% discount) ATLANTIS II 2x2 Including 2.5SE Software list price $1695 (less 15% discount) email: workshop@eegvermont.com Call 802-254-3305 to order Atlantis 2x2 or 4x4 |
Purchase BrainMaster's Atlantis at 15% discount off list price...! ATLANTIS 1 4x4 @ $2695 (less 15% discount) ATLANTIS II 2x2 @ $1695 (less 15% discount) Call 802-254-3305 or email workshop@eegvermont.com 2- HOUR free service & set-up with John N Demos, BCIA-EEG |
Built in impedance!! Works with MiniQ |